Smoke Detector Faulty and Solutions

Smoke Detector Faulty and Solutions

Views : 1292
Author : ASNEWARE
Update time : 2022-08-11 16:38:02

A smoke detector is a fire detection device that sends a fire signal to the panel when detecting the smoke from a fire. It can be applied in companies, houses, shops, warehouses and so on.

When a smoke detector reports faulty, what are the possible problems and what are the solutions?

1.The bus input voltage of the smoke detector is not within the range required.
Solution: Check the bus input voltage of the smoke detector and make sure that the voltage is within the range required by the smoke detector.

2.The communication of the smoke detector with a fixed address fails, or the smoke detector can be logged in, but its communication is unstable
Solution: The smoke detector may be damaged. It is suggestible to replace a new one

3.If the bus of the smoke detector is unstable, it might be the following reasons:
  • The communication wires are disturbed by electromagnetic fields
Solution: Choose the installation location of the smoke detector correctly, and do the wiring reasonably 
  • Some of the smoke detectors are damaged
Solution: Check the login results of the smoke detectors to find out the faulty rules and devices
  • Poor insulation of communication wires
Solution: Check the smoke detector with an insulation resistance meter. Add a moisture-proof rubber pad to the junction box or cover box of the smoke detector

4.The smoke detector has a poor connection
Solution: 
  • Check the wiring of the base terminal
  • Check whether the sheet metal between the base and the smoke detector is in poor contact

5.The smoke detectors have repeated codes or their address codes are repeated
Solution: Check the repeated codes and the smoke detectors that are not logged in
Related News
Read More >>
What is Fire Hose? What is Fire Hose?
Oct .13.2023
A fire hose is a highly pressurized hose that is used to bring water to the fire. It may also transport flame retardants. Fire hoses can be attached to either a fire engine or a fire hydrant, and the pressure is between 800 and 2000 kPa. For reasons of fire safety, it's quite important to have a fire hose inspection as well as all fire protection equipment tested.  If, during a fire emergency, the fire hose fails it could have disastrous results.
What is Water-proof Fire Alarm System? What is Water-proof Fire Alarm System?
Sep .15.2023
Waterproof Heat Detector
Fixed Temperature Waterproof Heat Detector, the detector uses a bi-metallic strip to sense temperature change, therefore consuming minimal standby current and providing high reliability.
The Detector is particularly suited to environments, which are exposed to high levels of condensation or are hosed down. The detector has a wide operating margin allowing it to respond to both slow and fast increases in temperature; it can also sense temperature reliably in a horizontal or vertical position.
Addressable Explosion-proof Fire Alarm System Introduction Addressable Explosion-proof Fire Alarm System Introduction
Aug .08.2023
The Explosion Proof range of products has been designed to provide protection against explosions and products to ensure that all major advantages of high-quality fire detection technology can be safely exploited in industrial and hazardous environments. Many difficult sites such as metal, paint, pipelines, chemical, pharmaceutical, oil refineries, and other installations are vulnerable to the risk of explosion. In order to protect the assets and people, they need special solutions for fast and reliable fire detection.
Emergency Lighting System Installation Guide Emergency Lighting System Installation Guide
Jul .20.2023
Emergency lighting system is divided into centralized controlling and non-centralized controlling type, or centralized power supply and non-centralized power supply type. This article talks about emergency lighting system, power supply, emergency light controller installation guide.